| Aluminum WiringInsight and understanding that only a Licensed Engineer can provide
The following is excerpted form the U. S. Consumer Product Safety Commission brochure, Publication 516 (REPAIRING ALUMINUM WIRING). Heimer® Engineering, P.C. is providing this for your information, and recommends that you check with the U. S. Consumer Product Safety Commission to see if they have any additional recommendations. Call 800.640.8090 or use the online form 24/7 for more information. On April, 28, 1974, two persons died in a home fire in Hampton Bays, New York. Fire officials determined that the fire was caused by a faulty aluminum wire connection at an outlet. Since that tragic accident, the U. S. Consumer Product Safety Commission staff and other government officials have investigated numerous complaints from homeowners throughout the nation who have had trouble with small gauge aluminum branch circuit wiring. The Commission has also had research conducted that shows that homes wired with aluminum wire manufactured before 1972 (“old technology” aluminum wire) are 55 times more likely to have one or more connections reach “Fire Hazard Conditions”** than is a home wired with copper. **The survey conducted by the Franklin Research Institute defined “Fire Hazard Conditions” to occur when receptacle cover plate mounting screws reached 149 degrees C (300 degrees F), or sparks were emitted from the receptacle, or materials around the receptacle were charred. The hazard investigated by the Commission staff occurs at connections to old technology aluminum wire, such as at outlets or switches or at major appliances such as dishwashers, furnaces, etc. Corrosion of the metals in the connection, particularly the aluminum wire itself, causes increased resistance to the flow of electric current and that resistance causes overheating. Homes built before 1965 are unlikely to have aluminum branch circuit wiring. Homes built, rooms added, and circuits rewired or added between 1965 and 1973 may contain aluminum wiring. In 1972, manufacturers modified both aluminum wire and switches and outlets to improve the performance of aluminum wired connections. Sale of the old style wire, switches and outlets still on dealer’s shelves however, continued after 1972. Trouble SignsSigns of trouble in aluminum wire systems include:
Unfortunately, not all failing aluminum wired connections provide such easily detected warning signs; aluminum wired connections have been reported to fail without any prior indications or problems. What the Homeowner Can DoIf you have noticed any of the trouble signs, have a qualified electrician determine whether the problem is caused by deteriorating connections to aluminum wiring. DO NOT TRY TO DO IT YOURSELF. You could be electrocuted or you could make the connections worse by disturbing them. If you are not certain whether your home has aluminum branch circuit wiring, you may be able to tell by looking at the markings on the surface of the electric cables which are visible in unfinished basements, attics or garages. Aluminum wiring will have “AL” or “ALUMINUM” marked every few feet along the length of the cable. (Note - the marking “CU-CLAD” or “COPPER-CLAD” in addition to the “AL” or “ALUMINUM” means that the cable uses copper-coated aluminum wire and is not covered by this message.) If you do have aluminum branch circuit wiring, the Commission suggests that you have a qualified electrician check the system for impending trouble. Remember, you may not have noticed any of the warning signs, but research shows that trouble may develop over time and an electrician may spot potential problems before you notice them. Can the Problem be Fixed?One method of eliminating the risks associated with old technology aluminum wiring terminations is to eliminate the primary cause: the aluminum wire itself. Depending upon the architectural style of your home and the number and locations of unfinished spaces (e.g., basements and attics), it may be relatively easy to rewire your home. A new copper wire branch circuit system would be installed, and the existing aluminum wire would be abandoned inside the walls. This is the most expensive method of repairing an aluminum wired home; but if you can afford the cost, it is also the best method available. Since it may be impractical to rewire some types of aluminum wired homes (e.g., condominium units), or since rewiring may be prohibitively expensive for some homes (e.g., split-levels with no unfinished areas), the Commission staff attempted to find a repair method which would permit the continued use of existing old technology aluminum wire. The main criteria to be met by such a repair method are:
The CPSC-sponsored research, laboratory tests, and demonstration projects identified only one method of repairing existing aluminum wire circuits which meet these criteria. That repair is known as the crimp connector repair. The crimp connector repair consists of attaching a piece of copper wire to the existing aluminum wire branch circuit with a specially designed metal sleeve and powered crimping tool. The metal sleeve is called a COPALUM parallel splice connector and is manufactured only by AMP Incorporated. This special connector can be properly installed only with the matching AMP tool. This tool makes a permanent connection that is, in effect a cold weld. An insulating sleeve is placed around the crimp connector to complete the repair. Two other repair methods are often recommended by electricians. While these repair methods are substantially less expensive than COPALUM crimp connectors, neither of these repairs is considered acceptable by the Commission staff.
EXCEPTION: If you have an aluminum wire termination in your home which exhibits symptoms of failure, twist-on connector pigtails or CO/ALR devices may be used as an emergency temporary repair for a failed aluminum termination. Should such a repair be performed, the Commission staff recommends that you arrange to have your home rewired or the COPALUM crimp connector repair performed as soon as possible. It is important to note that there is only one manufacturer of the special connectors and the tools required to make the repairs recommended by the CPSC staff. WarningThere are many other brands and types of crimp connectors including those intended to be installed with a pliers type of hand tool - which are readily available to consumers at hardware stores, lumber yards, hobby supply stores, automotive supply stores, and so forth. THE COMMISSION STAFF DOES NOT BELIEVE THAT THESE COMMON VARIETIES OF CRIMP CONNECTORS CAN BE USED TO RELIABLY REPAIR ALUMINUM WIRING. The Copalum Crimp Method of RepairThe precision dies in the COPALUM tool squeeze the connector and wires into a particular shape which was determined during the design of the COPALUM wire connector. Both the final shape of the connection and the amount that it is squeezed (deformed during crimping) are critical in making a reliable crimp connection. Upwards of 10,000 pounds of force is necessary to obtain the amount of deformation for which the connector is designed. In addition, electricians who are authorized to install COPALUM connectors are thoroughly trained by the manufacturer to use the tool properly. The Commission staff emphasizes that this training is necessary to assure that the electrician uses the careful, professional workmanship required to make the crimp connector repair safe and reliable. Crimping ProcedureFollow the procedure below with attention given to steps 1 through 4.
You should request a copy of AMP literature from your electrician prior to his beginning work. Discuss with your electrician any information in the literature which you do not understand. Remember every connection of aluminum-to-aluminum or aluminum-to-copper wire in your home should be repaired in order to obtain the maximum benefit from such repair work. All appliances connected directly to number 12 or number 10 aluminum branch circuit wiring (for example, dishwashers, cooking equipment, heaters, air conditioners and light fixtures) must be repaired in addition to wall outlets, switches, junction boxes and panel boxes. To determine whether the COPALUM crimp connection method of repair is available in your area, you may wish to write or call the manufacturer of the COPALUM connector for a list of authorized electricians who are doing aluminum branch circuit repair work in your area. You may write to: AMP IncorporatedAttn: Aluminum Wire Repair Program Mail Stop 140-13 P.O. Box 3608 Harrisburg, PA 17105-3608 PHONE: 1-800-522-6752 The Commission staff wishes to remind you that all modifications and additions to your wiring system should be done in accordance with local regulations and inspected by municipal authorities. You should insist that repairs to your aluminum wiring be inspected.
Call 800.640.8090, or click here to contact Heimer Engineering 24/7.
Home Page Environmental Topics Inspection Topics Inspection Photographs Heimer Engineering Locations:2810 Olinville Avenue, Bronx, New York 10467-7106 (718.547.2000)16 Court Street, Brooklyn, New York 11241-0102 (718.237.7777) 2171 Jericho Turnpike, Commack, New York 11725-2947 (631.858.5500) 71-34 Austin Street, Forest Hills, New York 11375-4721 (718.544.3000) 620 Middle Neck Road, Great Neck, New York 11023-1217 (516.487.2100) 459 Main Street, New Rochelle, New York 10801-6418 (914.576.6100) Seven Penn Plaza, New York, New York 10001-3900 (212.563.4777) 888 Huguenot Avenue, Staten Island, New York 10312-3920 (718.227.5000) 48E Main Street, Westhampton Beach, New York 11978-2632 (631.288.3900) This web site is best viewed with Microsoft® Internet Explorer version 7.0 or Mozilla Firefox 2.0. Other web browsers may not display this web site properly. Heimer Engineering's Licensed Professional Engineers are ready to serve your home inspection, building inspection, coop inspection, and condominium inspection needs. All Heimer Engineering's Licensed Home Inspectors are also Licensed Professional Engineers. HEIMER®, HEIMER INSPECTIONS®, FOR A GOOD LOOK®, WE LOOK GOOD®, and HEI-LITE® are registered trademarks of Heimer Engineering, P.C., 2171 Jericho Turnpike, Commack, NY 11725-2947. Terms of use Privacy Policy Professional Engineer Employment Opportunities This page was last reviewed on February 26, 2008. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||